Skip to main content

Macro Introduction

Start Macro

  • Set PRINT_START as the macro for starting a print, customizing actions before printing
  • Note that the macro name can be customized, as long as it is referenced in the slicer's start G-code
[gcode_macro PRINT_START]
gcode:
G92 E0 # Reset extruder
BED_MESH_CLEAR # Clear bed mesh
G28 # Home all axes
#Z_TILT_ADJUST # Gantry leveling
#quad_gantry_level # Gantry leveling
#G28 # Home all axes
G1 Z20 F3000 # Move nozzle away from bed
BED_MESH_PROFILE LOAD=default # Load bed mesh

Leveling and Bed Mesh Configuration Guide

I. Leveling Method Selection

  • Z_TILT_ADJUST and quad_gantry_level are mutually exclusive leveling solutions
  • Choose one based on your hardware architecture; do not use both simultaneously
  • If no corresponding leveling solution exists, delete or comment out the relevant configuration
  • It is recommended to home again after performing leveling

II. Bed Mesh Configuration Specifications

BED_MESH_PROFILE LOAD=default
  • Only a single bed mesh configuration can be loaded; multiple configurations cannot be enabled simultaneously
  • In BED_MESH_PROFILE LOAD=default, default is the preset configuration name
  • If no bed mesh has been created beforehand or if it is named differently, errors may occur

III. Standard Bed Mesh Probing Command

BED_MESH_CALIBRATE horizontal_move_z=2 METHOD=rapid_scan
  • horizontal_move_z=2: Nozzle lifting height during probing (unit: mm)
  • METHOD=rapid_scan: Use rapid scan probing method

IV. Adaptive Probing Command

BED_MESH_CALIBRATE adaptive=1
  • Simplified command specifically designed for automatic leveling sensors
  • Suitable for sensor systems such as TAP, klicky, PL08, etc.
  • Probing height and movement method are automatically controlled by the sensor, eliminating the need for manual parameters

End Macro

  • Set PRINT_END as the macro for ending a print, customizing actions after printing
  • Note that the macro name can be customized, as long as it is referenced in the slicer's end G-code
[gcode_macro PRINT_END]
gcode:
# Get Boundaries
{% set max_x = printer.configfile.config["stepper_x"]["position_max"]|float %}
{% set max_y = printer.configfile.config["stepper_y"]["position_max"]|float %}
{% set max_z = printer.configfile.config["stepper_z"]["position_max"]|float %}

# Check end position to determine safe directions to move
{% if printer.toolhead.position.x < (max_x - 20) %}
{% set x_safe = 20.0 %}
{% else %}
{% set x_safe = -20.0 %}
{% endif %}

{% if printer.toolhead.position.y < (max_y - 20) %}
{% set y_safe = 20.0 %}
{% else %}
{% set y_safe = -20.0 %}
{% endif %}

{% if printer.toolhead.position.z < (max_z - 2) %}
{% set z_safe = 2.0 %}
{% else %}
{% set z_safe = max_z - printer.toolhead.position.z %}
{% endif %}

M400 # Wait for buffer to clear
G92 E0 # Reset extruder to zero
G1 E-10.0 F3600 # Retract filament
G91 # Relative positioning
G0 Z{z_safe} F3600 # Raise gantry
G0 X{x_safe} Y{y_safe} F20000 # Move nozzle to remove string
M104 S0 # Turn off extruder heater
M140 S0 # Turn off bed heater
M106 S0 # Turn off part cooling fan
G90 # Set absolute coordinate system
G0 X{max_x / 2} Y{max_y} F3600 # Park nozzle at the back
BED_MESH_CLEAR # Clear bed mesh

Slicer Macro Settings

  • Select Printer
  • Select Beginner mode in the upper right corner, change it to Expert mode
  • Finally, select Custom G-code
    Loading...
  • Once Start G-code appears, you can proceed to the next step
    Loading...
Loading...