Skip to main content

Klipper Homing Timeout Issue

Problem Description

A communication timeout error occurs during the homing process:

Error during homing z: Communication timeout during homing

This mainly occurs during Z-axis homing with multiple MCUs. Klipper requires a response within 0.025 seconds.

Method 1: Adjust Timeout

Modify Timeout Configuration

sed -i 's/TRSYNC_TIMEOUT = [0-9.]*$/TRSYNC_TIMEOUT = 0.05/' ~/klipper/klippy/mcu.py

Restart Service to Apply

sudo systemctl restart klipper

Related Commands

# View current setting
grep "TRSYNC_TIMEOUT =" ~/klipper/klippy/mcu.py

# Restore default setting
sed -i 's/TRSYNC_TIMEOUT = [0-9.]*$/TRSYNC_TIMEOUT = 0.025/' ~/klipper/klippy/mcu.py
Prerequisites
  • Confirm Klipper is installed
  • Current user is the Klipper installation user
  • File paths are correct