Skip to main content

Klipper Homing Timeout Issue

Problem Description

Communication timeout error occurs during the homing process:

Error during homing z: Communication timeout during homing

This primarily appears during Z-axis homing with multiple MCUs, as Klipper requires a response within 0.025 seconds.

Method 1: Adjust Timeout Duration

Modify the timeout configuration

sed -i 's/TRSYNC_TIMEOUT = [0-9.]*$/TRSYNC_TIMEOUT = 0.05/' ~/klipper/klippy/mcu.py

Restart the service to take effect

sudo systemctl restart klipper

Related Commands

# View current setting
grep "TRSYNC_TIMEOUT =" ~/klipper/klippy/mcu.py

# Restore default setting
sed -i 's/TRSYNC_TIMEOUT = [0-9.]*$/TRSYNC_TIMEOUT = 0.025/' ~/klipper/klippy/mcu.py
Pre-checks
  • Confirm Klipper is installed.
  • The current user is the Klipper installation user.
  • The file paths are correct.
Loading...