Frequently Asked Questions (FAQ)
Please remember: Sending SET_PIN PIN=_probe_ready VALUE=0, under no circumstances will the light on the sensor side turn on. If the light is on or blinking, it indicates an issue with the wiring or configuration of the EN pin.
When the USB is connected to the computer, if the light on the sensor side is constantly on or blinking, it means you have not connected the EN pin to the motherboard control, or there is a configuration issue.
When the USB is connected to the computer, the pressure value output by pressing the sensor sometimes increases and sometimes decreases: This is normal, as both positive and negative pressure can be detected.
When the USB is connected to the computer, the displayed current pressure value has no relation to the threshold. If the trigger pressure is too high, simply set the threshold to a smaller value.